AVANTI SERVICE LIFTUser’s, Installation and Maintenance ManualModel Service Lift Pegasus

Seite 2

10AVANTI Service Lift for Wind Turbines Service liftCabin type Bucket type, front fence (1.1 m) with double doorService lift speed 19.4 m/min ± 10 % (

Seite 3

11 User’s Manual1. Top safety stop2. Top hatch3. Double door4. Main frame5. User control box6. Fixed front7. Anchor point for PPE8. Bottom hat

Seite 4 - Contents

12AVANTI Service Lift for Wind Turbines 3.6 General arrangement of Pegasus lift inside a generic wind turbine tower1. User control box in top platfor

Seite 5

13 User’s Manual3.7 Service lift dimensions

Seite 6 - 1. Limited Warranty

14AVANTI Service Lift for Wind Turbines 3.8 Main frameThe main frame is a welded steel structure. The traction and guiding system are bolted to the ma

Seite 7 - Additional instructions

15 !User’s Manual3.9 Controls3.9.1 Bottom platform control box3.9.2 Cabin control boxUP/DOWN LIGHTS (GREEN)Shines when the lift is going up or down r

Seite 8 - 2.2 Cautions

16AVANTI Service Lift for Wind Turbines 3.9.3 Top platform control box3.9.4 Mid tower junction box NOKOKUP/DOWN LIGHTS (GREEN)Shines when the lift is

Seite 9 - 3. Description

17 User’s Manual3.10 Service lift doorsMain access to the cabin is done through the double door system installed in the front. The system consists of

Seite 10

18AVANTI Service Lift for Wind Turbines 3.11 Top hatchThe service lift has a top hatch made of two sheets with hinges. This ensures that the hatch can

Seite 11 - 3.5 Service lift overview

19 User’s Manual3.12 Bottom hatchThe service lift has a bottom hatch made of one sheet which is opened inwards the cabin. It can be used in case of ev

Seite 13 - 3.7 Service lift dimensions

20STOPAVANTI Service Lift for Wind Turbines 3.14 Bottom safety stop The bottom safety stop will interrupt the up/down movement if:1) Encounters an ob

Seite 14 - 3.8 Main frame

21 User’s Manual3.16 Top and bottom mechanical stopsTop and bottom mechanical stops including buffers are installed on top and bottom of the la

Seite 15 - 3.9 Controls

22AVANTI Service Lift for Wind Turbines 3.19 Overload detection system Electronic equipment is installed inside the user control box. The overload de

Seite 16 - 3.9.4 Mid tower junction box

23 User’s Manual4.1 Good use Aspects to consider for a good use of the service lift: A. No person on the ladder when the lift is in operation. B. Th

Seite 17 - 3.10 Service lift doors

24AVANTI Service Lift for Wind Turbines 4.8 Emergency stop Release the UP/DOWN buttons and the service lift should stop. If it does not, push the eme

Seite 18 - 3.11 Top hatch

25 !User’s ManualPegasus Service lift maintenance is required and necessary: • Toavoidprematurewear• Toprolongthelifetimeofthemachine• To

Seite 19 - 3.13 Top safety stop

26AVANTI Service Lift for Wind Turbines 6.3 Yearly inspection6.3.1 Pinions Check carefully that the pinions are free from deterioration, damage or abr

Seite 20 - 3.14 Bottom safety stop

27 User’s Manual6.3.2.2 Looseness limit: To evaluate the looseness, check of control dimension “C” shall be between 57 and 59 mm.Rack replacement cri

Seite 21 - User’s Manual

28AVANTI Service Lift for Wind Turbines 6.3.5 Torques Assurance Check tightening torques of all screw connections with approved and calibrated torque

Seite 22

29 User’s Manual7. Repair in the event of breakdown STOPBreakdown Cause SolutionThe service lift will neither go up nor down!DANGER!Attempting to us

Seite 23 - 4. Lift Operation

Date of publication:1st CE Edition: 05/2012 Revision 3: 15/11/12 Manufacturer:Avanti Wind Systems SLPoligono Industrial CentroviaCalle Los Angeles n°8

Seite 24 - 5. Out of Service

30AVANTI Service Lift for Wind Turbines 8.Transport and StorageDepending on agreed transport and storage conditions with the customer, the following m

Seite 25 - 6. Maintenance

31 User’s Manual9.1.4 Tower support brackets The ladder rack is attached to the tower structure at a distance of max 3000 mm. The tower support brack

Seite 26 - 6.3.2 Ladder rack

32AVANTI Service Lift for Wind Turbines 9.3 Previous considerations All installation process must be made according to the installation drawing suppli

Seite 27 - 6.3.3 Counter Guiding roller

33 User’s Manual9.4.3 Bottom tower sectionA. Follow same installation instructions as on points A and B for intermediate tower section. B. Position

Seite 28 - 6.4 Ordering spare parts

34AVANTI Service Lift for Wind Turbines D. Take the service lift down and loosen the anchorages screws to the tower of each ladder section. E. Turn

Seite 29

35 User’s ManualF. Go up with the service lift to the next tower section flange. Tighten all the ladder anchorage – ladder bracket screws M12 above th

Seite 30 - 9. Installation

36AVANTI Service Lift for Wind Turbines Appendix A: Safety measures when using AVANTI Pegasus liftsEvacuation through BOTTOM hatch: 1. User(s) attac

Seite 31 - 9.2 Cautions

AustraliaAvanti Wind Systems PTY LTDUnit 15 / 160 Lytton Road Morningside 4170 · QueenslandP: +61 (0) 7 3902 1445 · F: +61 (0)7 3902 1252ChinaAvanti

Seite 32 - 9.3 Previous considerations

4AVANTI Service Lift for Wind Turbines Page1 Limited Warranty ...6 2 Cautions...

Seite 33 - 9.5 Assembly on site

5 User’s Manual6 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 34 - ATTENTION!

6AVANTI Service Lift for Wind Turbines Avanti Wind Systems A/S warrants that com-mencing from the date of shipment to the Customer and continuing for

Seite 35 - 10. Disassembling

7 STOP!User’s ManualSymbol Signal word Meaning Possible injury if not observedSafety instructionsDANGER!IMMEDIATE orpossibly imminentdanger:Death or

Seite 36 - Appendix A:

8STOPAVANTI Service Lift for Wind Turbines 2.2 Cautions CAUTION! Avoid injury – follow all instructions!a) Installation and/or maintenance and/

Seite 37

9 User’s Manual3. Description3.1 PurposeThe Service Lift described in this User’s Manual serves the following purposes: - Transportation of staff and